    REFLEX LEVEL GUAGE

    WORKING PRINCIPLE 

    Reflex glass level gauges working principle is based on the light refraction and reflection laws Reflex glass level gauges use glasses having the face fitted towards the chamber shaped to have prismatic grooves with section angle of 90. When in operation, the chamber is filled with liquid in the lower zone and gases or vapors in the upper zone; the liquid level is distinguished by different brightness of the glass in the liquid and in the gas/vapor zone. The reflex level gauges do not need a specific illumination: the day environmental light is enough. Only during the night an artificial light must be provided. The different brightness in the two zones is obtained as explained below:

    LIQUID ZONE 

    This zone appears quite dark when the gauge is in operation and lighted as above said. Given the construction, most of the environmental light rays incident on the external face of the glass are quite perpendicular to said face and therefore, not deviated by the glass. These rays reach the glass/liquid interface with an inclination of approx. 45. The critical angle glass/liquid is always superior to 45. Therefore the rays incident within the critical angle (practically the totality) are refracted within the liquid and, since the internal walls of the gauge chamber are not reflecting, the rays cannot be seen from the outside. In fact the zone will appear dark, nearly black, to the observer.

    LIQUID ZONE 

    This zone appears almost silver bright to the observer. As for the liquid zone, the light rays reach the glass/gas-vapor interface with an angle around 45. Since this angle is greater than glass/gas-vapor critical angle, the rays are not refracted , but totally reflected making 90 turn, thus reaching the nearest glass/gas-vapor interface again with angle of 45. For same reason they will be reflected and turned by 90 towards the observer, to whom the zone will appear silver bright.

    APPLICATIONS 

    Reflex glass level gauges can be used in most of the cases and offer great advantages in terms of: low initial cost, low operating cost, easy level reading.
    Reflex level gauges cannot be used in certain cases as for example:

    • When the separation level between two liquids has to be read (interface)
    • When besides the level indication, the observation of the liquid colour is required
    • When the process fluid is high-pressure water steam, since in this case the glass must be protected from the solvent action of the boiler water by using mica shields
    • When the process fluid is such that can corrode the glass (e.g. high temperature
      alkal ine solut ions or hydrof luor ic acid) , since ica shields or
      Polytrifluorochloroethylene shields must be used to protect the glass

     

    Trade Information
    • 700 Per Month
    • 10-15 Days
      Related Products
      Bypass Rotameter


      Send Inquiry
      Orifice Plate Flow Meter


      Send Inquiry
      Transparent Level Indicators


      Send Inquiry
      Tubular Level Indicator


      Send Inquiry
      Pressure Transmitter with Local Indicator( as LPI with retransmission)


      Send Inquiry
      Oxygen Rota Meter


      Send Inquiry
      right arrow
      left arrow
      Contact Us

      B No. 14/4, Balli Nagar, Near Mewla Maharajpur Metro Station, Faridabad, Haryana, 121010, India
      Phone :+918045803036